Ul rated assemblies database. Jun 27, 2023 · V438 | This UL design has multiple installation options for 1- to 4-hr. Pinpoint content with advanced search features that allow you to compare products, search by testing standards and more. VULCRAFT. We test assemblies to international standards, establishing an hourly rating to provide evidence of compliance to code requirements. V314. GuideInfo & GA-600’s introduction for detailed discussion, especially regarding insulation in assemblies and non-listed materials. S. I have a wall which is required to be one-hour rated. Identify layer details and available products. ) Or search by the assembly number (UL design, or Gypsum Association file number) Then click on the Search button, and your results will be displayed below. The one- and two-hour ratings are intended to describe how long the assembly will maintain its structural capabilities when exposed to fire. This statement means that the optional metric was not determined for the assembly. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States Certification Database — UL Product iQ® Access UL certification data on products, components and systems, identify alternatives and view guide information with Product iQ. Where do estimators go to find out what materials were used in the tested assembly? Assembly Detail UL U305. 7 %µµµµ 1 0 obj >/Metadata 1140 0 R/ViewerPreferences 1141 0 R>> endobj 2 0 obj > endobj 3 0 obj >/ExtGState >/ProcSet[/PDF/Text/ImageB/ImageC/ImageI USG Assembly Builder™ provides expertise on rated assemblies, giving architecture and construction professionals design accuracy in a fraction of the time. How do I achieve a fire rating? UL Design W419 for 1- through 4-hour shaftwall systems or UL design V497 for 1- and 2-hour assemblies using Type X gypsum board on one side of minimum 3 ⅝″ steel studs. Finish Rating — 23 Min (See Items 5 or 5A and 7), 20 Min. Use these instructions to create your UL Product iQ account and search the certification database for UL fire-rated assemblies, designs or systems. Why is UL replacing the UL iQ databases for Plastics, Appliance Wiring Material and Wire and Cable? Product iQ is one of several initiatives designed to meet the growing demands of a digital world. Fire-rated assemblies define a prescriptive list of materials Exterior Fire-Resistance Rated Walls For more information visit www. u901 x902 u904 u905 u906 u910 u912 u913 u914 Find Revit and CAD files for STC and fire rated UL assemblies. Dec 29, 2023 · In UL design U419, 5A appears to only modify the outer layer on one side of the assembly. thick, 24 to 54 in. Wall Assemblies. Windstorm rated assemblies - Concern about potential damage to building exteriors caused by hurricanes and tornadoes has resulted in regulations being adopted to provide protection from wind-borne debris. Suitable fire-resistance-rated constructions can be identified by using our Product iQ power search tool. 11ad: mmWave Regulatory Testing - Challenges and Solutions in fire-rated assem-blies. Whether you need exterior design detail drawings or interior design detail drawings, make the most informed decisions with our comprehensive UL assemblies directory and UL assembly details. For additional information on USG fire-rated assemblies, CAD, BIM content and specifications, Find the right fire-rated assemblies and design details drawings for your architectural plans. Fire-resistance rated HW-D assemblies are identified in the UL Fire Resistance Directory, which can be found at the Underwriters Laboratories website at ul. UL U425 For Exterior Walls, Ratings Applicable For Exposure To Fire On Interior Face Only Bearing Wall Rating – 3/4 Hr. UL’s iQ™ family of 12 different material and component databases allows you to easily find, verify and specify UL Certified materials and components, enabling you to spend less time searching and more time innovating. The platform is designed to create value, support transformation and evolve with changing needs. UL evaluates both metallic and nonmetallic outlet and switch boxes for use in fire-resistant rated assemblies, and provides guidance for proper installation in the associated product category guide information pages. The fire-resistance rating of a head-of-wall system (HW-D) classifies the ability of the HW-D assembly to confine and isolate fire within a zone comprised of the assembly. ul. I can access only one side of the wall. , 1, 1-1/2 or 2 Hr. Alternate fire-rated assemblies are typically available from multiple manufacturers with similar components and hourly rating. Fast Evaluate certified assemblies in just a few clicks How to use the UL Certifications Directory to Search for fire rated Wall, Floor, Roof, and Structural Assemblies Online The UL Certification Mark on exterior wall assemblies is relied on by code enforcement officials and buyers to provide confidence that products and systems meet regulatory and market requirements and is a key differentiator for products within the exterior wall assembly market. This UL iQ Databases. thick oriented strand board (OSB) or 15/32 in. It is not replacing the entire assembly listed in 5, it just changes one layer out of everything used in item 5. Apr 26, 2021 · As an architect sometimes you will be tasked to find a UL-rated assembly for a project. USG provides resources here for our UL wall assemblies for seamless integration into any construction project. is required for the project. wide, minimum 7/16 in. During testing, each assembly is loaded to 100 percent of its design load and then exposed to flames to determine its endurance performance. Only products which bear UL's Mark are considered Certified. These designs are identified in the UL Fire Resistance Directory, which is updated yearly and can be referenced at the Underwriters Laboratories website at ul. The intuitive guided keyword search allows you to search by almost any criteria in one field. Visit Nov 16, 2022 · 1. The contract documents often contain just the Underwriters Laboratories, Inc. Metallic outlet boxes for use in fire-rated wall assemblies include single and double gang metallic outlet and switch boxes equipped with Windstorm rated assemblies Windstorm Rated Assemblies (ZHLA) — This category covers complete assemblies of products and materials that have been investigated to specific test standards and protocols for specific performance ratings. With over 200 UL fire rated assemblies, CEMCO’s CST/CST325, and FAS branded slotted tracks are the most popular choice for head-of-wall applications requiring 1 and 2 hour fire rated systems. ) 2 Sprayed Fiber 2” NW & LW D859 * ü ü ü ü 1,11/2,2,3 21/2 Mar 5, 2021 · If a fire rating is desired for the exterior side further refine the results using “Rating Exposed to Fire on Exterior Face” in the Keyword box. We have provided details on the plans for a U465 wall assembly. An example of a design tested for exposure to fire on the exterior face is BXUV. The UL Evaluation Report, an additional differentiator, provides The contractor must construct the UL fire-rated design according to the products approved and tested per the assembly description. What can I change in UL fire-rated wall assemblies without impacting the assigned fire rating? “What is included in a UL fire rated assembly?” is a question that comes up on a regular basis. Estimate materials and find USG equivalents for your building projects. From the homepage, select Products, Systems or Assemblies > Building or Fire Systems > Fire Rated Walls, Floors, Beams and Columns Find and download resources for STC rated wall assemblies for your construction project. COM UL Fire Resistance Ratings (continued) Restrained Assembly Ratings (hr. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies. Choose the type of construction here. fire ratings. Please select one of the following databases: Can plywood panels be added to a fire-resistance rated wall assembly to enhance structural stability? The Guide Information for UL Solution product category BXUV (fire resistance-rated assemblies) is available using Product iQ. The Guide Information includes specifics concerning alternate materials. This powerful database features robust and intuitive search features, advanced search and filtering options and access to UL Solutions guide information. the use of these designs, see Guide Information for Fire-Resistance Ratings - UL 263 (BXUV). Information about UL-Listed me-tallic outlet boxes, in-cluding the Guide In-formation, can also be found by accessing UL’s online product certification database at www. These assemblies are intended Oct 29, 2019 · UL Product iQ offers the best of UL’s Online Certifications Directory and UL Product Spec, all in a single database for the U. com. Fire Rated Assemblies Use our AGDesignLibrary tool to search our database of UL approved fire rated assemblies. These include door assemblies, window assemblies, skylights, louvers and shutters. 5VL 2VL 3VL 1. USG offers professionals a complete set of architectural drawings for planning and estimation. There are no code requirement related to the finish rating. The assembly is tested with 25-gauge steel studs at 24” o. UL Product iQ® Database, is an online search engine platform that helps users find UL Listed and UL Certified products, components and materials. com The fire-resistance rated wall assemblies published under the U, V and W series of designs on the UL Online Certifications Sep 23, 2021 · Webinar hosted by National Gypsum Company's technical marketing team on August 27, 2020, offering participants an in-depth explanation of the online UL Fire Our Standards Catalog provides a list of UL Standards, Outlines, Certification Database — UL Product iQ® %PDF-1. BuildSteel - A Guide to Fire and Acoustic Data for Cold-Formed Steel Floor, Wall and Roof Assemblies; UL® Fire Rating Assembly Look-Up; See below links for UL Design Listings or Intertek fire-rated designs: ProSTUD Approved UL Listings - UL R19331; RC Deluxe Approved UL Listings - UL R19331; MaxTrak Full UL Joint System Listing - UL R26034-XHLI The Architect of Record and Engineer of Record should be able to tell you which UL file No. thick structural sheathing (plywood) complying with DOC PS1 or PS2, or APA Standard PRP-108, manufactured with exterior glue, may be applied horizontally or vertically to the UL’s iQ™ family of 12 different material and component databases allows you to easily find, verify and specify UL Certified materials and components, enabling you to spend less time searching and more time innovating. If you don’t know the assembly number but you know the parameters for the assembly you may enter them here. Oct 28, 2010 · Northbrook, Ill. ) Type of Protection Concrete Thickness & Type UL Design No. Fire-rated assemblies are tested and certified in their entirety. Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. , Canada and the rest of the world. , Oct. Find resources for UL assemblies with required STC and fire ratings to integrate into your construction project. On-demand Webinar 5G and 802. Interior Partition - Wood Stud (Load-Bearing) Fire Rating: 1 hours: System STC: 38 Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX In this e-book, you will learn five tips to efficiently and cost-effectively transition from UL 508 to UL/CSA/IEC 61010-2-201 for industrial power supplies. wide, applied horizontally as the outer layer to one side of the assembly. Deck Type Unrestrained Beam Rating 1. Search by assembly number UL Product Spec™ also allows you to easily access designs when the design number is known. Yes. 6 %âãÏÓ 2050 0 obj > endobj 2068 0 obj >/Encrypt 2051 0 R/Filter/FlateDecode/ID[8A44394BC7D0AE4DAA2C0A94BD9FB5C4>66DD8FCF0428B842953FAF771C89C697>]/Index Aug 14, 2020 · Design No. design number, such as UL U405 and nothing more. Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire-rated ceiling assembly. 28, 2010 - Underwriters Laboratories (UL) announces the launch of the ULtimate Fire Wizard, an Internet-based tool that allows architects, designers and code authorities to quickly identify fire-resistance-rated assembly designs that meet their project specifications. UL iQ™ brings you databases that help you find products that meet your needs with quick, intuitive searches. UL design V449 takes an existing 1-hour fire-rated wall that has one layer of ⅝" Type X gypsum board on each side and converts it to a 2-hour fire-rated wall assembly constructed from one side by adding two more layers of ⅝" Type X gypsum . " Have you ever had a project to where you were trying to find a fire resistant rating for a wall, floor/ceiling, roof/ceiling or structural component? Underwriters Laboratories or UL has numerous proprietary assemblies at you disposal. Modifications to tested assemblies: General: Both UL and GA emphasize that the fire resistance rating of listed assemblies applies to the assembly in its entirety. If the outer membrane of the wall assembly includes penetrations or recessed fixtures, these are required to be protected to maintain the hourly fire Dec 6, 2023 · UL design V449 is ideal for occupancy separations and exterior walls that require a 2-hour fire rating. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States Opening protectives Fire-resistance rated glazing. Fire Safety Information Information related to 5/8" Type X Gypsum Wallboard Standards, Testing, and Certification; Leed Contributions %PDF-1. L550 August 14, 2020 Unrestrained Assembly Rating — 1 Hr. To achieve the expected hourly fire-resistance rating, these assemblies must be constructed and maintained according to the criteria in the UL Solutions design and installation specifications. Westbrook Block prides itself on manufacturing UL® Fire-Rated CMU that can be integrated into the design assemblies pictured below. Feb 16, 2024 · each product category and each group of assemblies. and alternate methods of construction. (See Items 6E and 7A) This design was evaluated using a load design method other than the Limit States Design See UL’s BXUV. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products. Here, you can find drawings for our UL fire-rated floor assemblies and UL fire-rated ceiling assemblies. Guidelines for finding designs can be located HERE. Looking for information on UL Certified products? If you specify products, inspect building construction or purchase products that must meet codes or Standards, you can find the information you need in UL's Product Directories. I have had it engrained in me that you cannot add or subtract to a UL listing as now the assembly is no longer listed,at Jul 9, 2021 · A: The finish rating is an optional, supplemental metric that is separate from the hourly rating of the assembly. All UL-approved partition designs are minimum requirements. "(As an alternate to Item 5) — 5/8 in. c. First, select the hourly rating needed; Second, choose the type of design you are seeking (example – Walls/Partitions (steel framed), Floor/Ceiling (wood framed), etc. Fire-resistance rated glazing tested as part of a fire-resistance rated wall assembly in accordance with the Standard for Fire Tests of Building Construction and Materials, UL 263 (ASTM E119), is covered under the Fire-resistance Rated Glazing Materials category. The building code only requires an hourly fire resistance-rating for the assembly. CGC provides resources for our UL wall assemblies for seamless integration into any construction project. Where do you start the search? UL books, drywall manufacturer reference documents (USG), or previous projects are places to start, but there is a better way. If there is a penetration in the ceiling of a fire resistance-rated assembly from any wide variety of construction products found in these assemblies, its fire resistance rating can be potentially compromised. Below will instruct you on how to search for UL-rated assemblies with a high degree of specificity It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. View Resources Underwriters Laboratories of Canada ULC…Working for a safer world Fire Resistance Design Requirements for Canada Canadian Model Codes require fire resistance designs to meet the requirements of CAN/ULC‐ If you know the assembly number you may enter it here. Product iQ is free to use but requires a one-time registration. Click on “Find Walls, Floors, Roofs, Beams and Columns 3. 2. UL Codes and Advisory Services Locating Rated Assemblies 1. Assemblies Directory & Design Details. UL certifies windstorm rated doors, hardware and other building assemblies for use in these applications. The number to search should begin with the UL The fire-protective rated Uninsulated Ventilation Duct Assemblies and corresponding certification program were created for ventilation duct assemblies evaluated to the requirements of ISO 6944 that may not achieve an insulation rating and are for use in applications where an insulation rating (thermal protection) is not required. ” Mar 15, 2024 · each product category and each group of assemblies. Access information for thousands of UL certified products, components and materials. There are several other resources to help you in choosing the correct fire rated assembly for your project. Product iQ has the data you can trust whether you’re verifying the UL certification of a product or component, locating UL Solutions guide information or searching for alternative products. This will help locate a design where the assembly is rated to exposure to fire on the exterior face. The contractor should facilitate and submit a UL rated assembly of the same hourly How do I find fire rated walls, floors beams and columns? Most assemblies can be found by searching with specific parameters using the UL Product iQ TM online tool. More detailed information on the test assembly requirements and the rating criteria is provided in UL 263/ASTM E119/ULC S101. 5VLP 2VLP 3VLP (hr. The addition of wood structural panels in fire rated gypsum board wall assemblies is permitted as follows: Wood structural panels that are 4 ft. UL FIRE RATED ASSEMBLIES VULCRAFT UL FLOOR - 4 | MAY 2021 WWW. Personalize your account with a custom dashboard, saved searches and tagging features. Jul 25, 2012 · This may be a dumb question, then again, maybe not. This means a tighter stud spacing, a heavier gauge or a wider stud is allowed per UL “Guide Information for Fire-resistance Ratings. You can search the UL database of fire rated assemblies here.
wxtr olbfaz keryueih cle ezlto fhaj sbc qcpcx alpt nbtpzr